3 research outputs found

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    Get PDF
    Abstract Background This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p Conclusions In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH

    An FPGA-based parallel processor for Black-Scholes option pricing using finite differences schemes

    No full text
    Summarization: Financial engineering is a very active research field as a result of the growth of the derivative markets and the complexity of the mathematical models utilized in pricing the numerous financial products. In this paper, we present an FPGA-based parallel processor optimized for solving the Black-Scholes partial derivative equation utilized in option pricing which employs the two most widely used finite difference schemes: Crank-Nicholson and explicit differences. As our measurements demonstrate, the presented architecture is expandable and the speedup triggered is increased almost linearly with the available silicon resources. Although the processor is optimized for this specific application, it is highly programmable and thus it can significantly accelerate all applications that use finite differences computations. Performance measurements show that our FPGA prototype triggers a 5× speedup when compared with a 2GHz dual-core Intel CPU (Core2Duo). Moreover, for the explicit scheme, our FPGA processor provides an 8× speedup over the same Intel processor.Παρουσιάστηκε στο: Design, Automation and Test in Europe Conference and Exhibitio

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    No full text
    Background: This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods: Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results: A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p < 0.001). WCH phenomenon (high OBP with low HBP) was observed in 22.7% of the patients, MUCH (low OBP with high HBP) in 15.8%, uncontrolled hypertension (high OBP with high HBP) in 29.9%, and controlled hypertension (low OBP with low HBP) in 31.6%. In multivariate logistic regression analysis, WCH was determined by stage-1 systolic hypertension (odds ratio [OR] 8.6, 95% confidence intervals [CI] 5.7, 13.1) and female gender (OR 1.6, 95% CI 1.1, 2.4), whereas MUCH was determined by high-normal systolic OBP (OR 6.2, 95% CI 3.8, 10.1) and male gender (OR 2.0, 95% CI 1.2, 3.1). Conclusions: In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH. © 2019 Hellenic Society of Cardiolog
    corecore